Açıklama |
: |
MANYETİK DUYARLILIK TERAZİSİ (MAGNETIC SUSCEPTIBILITY METER) For innovation in magnetic measuring instruments MS2 Magnetic Susceptibility System Specification - MS2 Meter Measuring range - volume specific 1-9999 x 10-5 SI (10-6 CGS) - mass specific 1-9999 x 10-8 SI (10-6 CGS) Resolution - volume specific 2 x 10-6 SI (2 x 10-7 CGS) on x0.1 range. The resolution achieved will depend on temperature drift and environmental noise. Internal battery 0.6 Ah sealed Ni-Cad give 8 hours continuous use before recharge is required. Enclosure material high impact ABS Operating temperature -100C to 400C Weight 1.2kg Dimensions 260 x 158 x 50mm Sensor cable 50 ohm TNC to TNC, 1m length (alternative lengths to 100m on request) Battery charger inlet 2.1mm socket, 6-18Vd.c., 100mA maximum, polarity protected RS232 interface 1200/9600 baud selected on rear panel Interface connector 4-way rear panel Fischer socket The MS2 magnetic susceptibility system comprises a meter with a wide range of sensors for measuring the magnetic susceptibility of soils and rocks, in both the field and laboratory, with a resolution to 2 x 10-6 SI units. Equipment is available for the measurement of susceptibility over the temperature range -200ºC to +850ºC. Applications include geological and soil surveys, palaeomagnetics, archaeological prospecting, palaeoclimatic studies, hydrology, sedimentology, core logging/correlation and magnetic fabric analysis. In archaeology, this system can be used to detect the enhancement of magnetic susceptibility in soils produced by human habitation, mainly due to burning. The measurements are non-destructive, and the low frequency used ensures that the results are largely unaffected by sample conductivity. The probes are temperature compensated to minimise drift during measurements. With a unique range of sensors the Bartington MS2 system is well established as the world standard for field and laboratory use.
MS2 Magnetic Susceptibility Meter The MS2 meter can be connected to a wide range of individually calibrated sensors. When sample material is placed within the influence of the low frequency, low intensity, alternating magnetic field produced by the sensor, a change in frequency results. This is converted to a value of magnetic susceptibility, which is displayed digitally in SI or CGS units, as selected. Diamagnetic (negative) values can be measured. The instrument is powered from internal batteries, rechargeable from the mains or a vehicle dashboard, with indicators for battery status and charging. Push buttons or a toggle switch are used for zeroing or taking measurements. A serial interface provides computer control and data transfer. A range switch adds one place of decimal to the resolution with an increased measurement time. All sockets and switches are environmentally sealed. The MS2 meter is portable and is supplied with a carrying bag for field use, an instrument stand for laboratory use, a universal mains adaptor, vehicle dashboard connector, RS232 cable and a booklet on Environmental Magnetic Susceptibility measurements. MS2 Magnetic Susceptibility System Specification - MS2B Sensor Calibration accuracy 1% (10ml calibration sample provided) Measurement period: x 1 range 1.5s SI (1.2s CGS) x 0.1range 15s SI (12s CGS) Operating frequencies: LF 0.465kHz ±1% HF 4.65kHz ±1% Amplitude of applied field 250μT peak ±10% (LF & HF) Maximum resolution 2 x 10-6 SI (vol) (2 x10-7 CGS) (LF & HF) HF/LF cross calibration 0.1% worst case (can be adjusted using calibration sample) Temperature induced drift: sample to sensor differential ±0.05 x 10-5 SI/ºC/minute (LF& HF) (±0.05 x 10-6 CGS/ºC/minute) Enclosure material high impact ABS Weight 0.7kg Dimensions 210 x 145 x 110mm MS2B Dual Frequency Sensor This sensor is used for mass or volume specific susceptibility measurements of standard palaeomagnetic samples in studies of rock and mineral magnetism. It is also used in conjunction with the AMSWIN-BAR software and sample adaptor for measurements of the anisotropy of susceptibility. The unique dual frequency facility permits identification of ferrimagnetic grains close to the superparamagnetic/stable single domain transition. This information is critical to many aspects of interpretation, for example in studies of weathering and soil formation, fossil soil identification and characterisation, and sediment or dust source investigations. The sensor accepts 10ml and 20ml cylindrical bottles, 25.4mm and 23mm cubic boxes, 35mm pots and 25.4mm cylindrical cores. A manually operated platen allows the sample to be inserted and positioned centrally within the sample cavity. A calibration sample with low temperature and frequency dependency is supplied with the sensor. Dual frequency cross calibration is quickly accomplished with the use of the calibration sample and adjuster tool. Specification - MS2C Sensor Loop internal diameter 36, 40, 45, 60, 72, 80, 90, 100, 125, 130, 135, 140, 145, 150, 160 or 162mm Intermediate sizes can be provided at an additional charge Calibration accuracy 5% (calibration sample provided) Measurement period - x 1 range 1.1s SI (0.9s CGS) - x 0.1range 11s SI (9s CGS) Operating frequency 0.565kHz Drift at room temperature <2 x 10-5 SI (vol) (<2 x 10-6 CGS) in 10 minutes after 5 minutes operation MS2C Core Logging Sensor A series of loop sensors, ranging from 36 to 162mm in diameter is available for high resolution volume susceptibility measurements on whole cores. They are suitable for measuring any type of peat, lake, or marine sediment core, provided it is not metal clad. These rugged sensors, with a very low temperature induced drift, are designed for laboratory, field or shipboard use. They can be used with manual or automated core analysis systems - details on request. The MS2C sensors are used in prospection, core correlation and the identification of palaeoclimatic sequences. Optimum measurement accuracy is achieved with 5-10mm core clearance. Calibration graphs are provided for varying core to sensor diameter. This loop probe is designed for rapid assessment of the concentration of ferrimagnetic materials in the top 100mm of the land surface. It is used in studies of slope processes, and in archaeological prospecting. The probe can only be operated in conjunction with the MS2 probe handle. MS2E Sensor This sensor is designed to perform high resolution measurements on the surface of split drill or soft sediment cores. The sensitive area of the probe, as defined by 50% maximum response, is in the form of a rectangle of 3.8mm x 10.5mm allowing very fine resolution surface measurements. The position of the long axis is identified by marks on the circumference of the sensor. The sensor is supplied in a protective case. MS2D Probe Specification - MS2E Sensor Area of response 3.8mm x 10.5mm at the end of the ceramic cylinder Depth of response 50% at 1mm, 10% at 3.5mm Measurement period - x 1 range 1.5s SI (1.2s CGS) - x 0.1 range 15s SI (12s CGS) Operating frequency 2kHz Drift at room temperature <5 x 10-5 SI (vol) (<5 x 10-6 CGS) in 5 minutes after 5 minutes operation Enclosure material diecast aluminium and ceramic Weight 0.22kg Dimensions 150 x 50 x 25mm Specification - MS2D Probe Depth of response 50% at 15mm, 10% at 60mm Measurement period - x 1 range 0.6s SI (0.5s CGS) - x 0.1 range 6s SI (5s CGS) Operating frequency 0.958kHz Drift at room temperature <10 x 10-5 SI (vol) (<10 x 10-6 CGS) in 20 minutes after 20 minutes operation Enclosure material reinforced epoxy Weight 0.5kg Dimensions mean diameter 185mm, overall height 90mm MS2F Probe This miniature probe is ideal for the stratigraphic study of exposed geological and archaeological sections. It is also used where difficult surface conditions prevent good contact with the MS2D loop. The probe can only be operated in conjunction with the MS2 probe handle. Specification - MS2F Probe Area of response end face and cylinder wall up to the shoulder Depth of response 10% at 6mm from end face and 4.5mm from outer diameter of end cap Measurement period - x 1 range 1.1s SI (0.9s CGS) - x 0.1 range 11s SI (9s CGS) Operating frequency 0.58kHz Drift at room temperature <10 x 10-5 SI (vol) (10 x 10-6 CGS) in 20 minutes after 20 minutes operation Enclosure material Nylon 66 Weight 0.05kg Dimensions - sensitive volume 15mm diameter x 20mm - overall 35mm diameter x 85mm Specification - MS2G Sensor Calibration accuracy 2% (1ml calibration check sample provided) Measurement period - x 1 range 0.9s SI (0.7s CGS) - x 0.1 range 9s SI (7s CGS) Operating frequency 1.3kHz Drift at room temperature <2x10-5 SI (vol) (<2x10-6 CGS) in 5 minutes after 5 minutes operation Enclosure aluminium and ceramic Sample cavity dimensions 8.5mm diameter x 28mm in height Sensitive region 5mm height at centre of cavity Weight 670g Dimensions (mm) 185 x 93 x 69mm Sample vial - 1ml volume Kartell part number 730 MS2G Sensor This sensor is designed for magnetic susceptibility measurements of 1ml liquid or powder samples. Scaling correction values are given for volumes down to 0.2ml. The sensor operates at a low frequency and has excellent temperature stability. It is used for susceptibility measurements where only very small samples of homogeneous fine-grained material are available. Examples are airborne particulates collected in filter papers or particles in colloidal suspension. The sensor accepts commercially available polythene vials with a diameter of 8mm and a length of 30mm. The sample holder is compatible with other rock measuring equipment allowing for a comprehensive range of measurements to be taken without the need for re-packing the sample. The sample cavity is situated at the tip of a boom mounted on the aluminium electronics enclosure. Specification - MS2K Sensor Area of response 25.4mm diameter full-width-half-maximum Depth of response 50% at 3mm, 10% at 8mm Measurement period - x 1 range 1.2s SI (1s CGS) - x 0.1 range 12s SI (10s CGS) Drift at room temperature <2 x 10-5 SI (vol) (<2 x 10-6 CGS) in 5 minutes after 5 minutes operation Operating frequency 930Hz Weight 0.32kg, (1.20kg with carrying case) Dimensions 165 x 145 x 50mm Environmental May be used under wet conditions - not suitable for immersion MS2K Sensor This sensor is designed to provide highly repeatable measurements of the volume magnetic susceptibility of moderately smooth surfaces. Applications include description of magnetic stratigraphy and identification of horizons. It can also be used for characterisation of outcrops and logging split cores, with the exception of metal-clad cores. The sensor has applications in materials testing where the relatively low operating frequency permits measurement on some of the less electrically conductive metal alloys, for example stainless steel, without magnetisation. MS2H Sensor The MS2H is a down-hole sensor for profiling the magnetic susceptibility of strata in 25mm nominal diameter auger holes. The detachable probe is fitted to the lower end of a push-tube to give an assembled length of 1 metre. Waterproof screw couplings allow further 1 metre extension tubes to be added to achieve any practical length. The probe assembly is hand-guided within the hole during logging and graduations ensure depth control to a resolution of 1cm. The probe connects to the MS2 meter via a 5mm diameter cable which may be extended to any practical length. The region of magnetic investigation radiates uniformly around the end of the probe resulting in tolerance to inhomogeneities. Strata as narrow as 12.5mm in thickness can be discriminated. Measurements to a precision of 1 x 10-5 SI (volume) are obtained in less than one second. A low operating frequency of 1.3 kHz ensures immunity to electrical conductivity effects. Multisus software can be used to log data during surveys. Suitable augers can be supplied - information on request. Applications include cultural stratigraphy in archaeology, geomorphology, landslide characterisation, paleosol identification, pedology, erosion studies and stratigraphic correlation. Specification - MS2H Sensor Spatial resolution (vertical FWHM) 12.5mm full width half maximum Depth of horizontal penetration 50%/2mm, 10%/5.5mm, 1%/13mm Pattern of investigating field Isotropic radial Operating frequency 1.3kHz Precision 1 x 10-5 SI (1 x 10-6 CGS) Calibration accuracy _5% in ø22mm sample Measurement period (x1 range) 0.95s (on SI range) Thermal drift (typical) 2 x 10-5 SI/ºC (below 20ºC) -1 x 10-5 SI/ºC (above 20ºC) Thermal setting time (typical) 30s/ºC (step change) Markings for plane of sensitivity Lowest graduation ‘O’ Ring seal 1cm graduations Lowest graduation Lower push-tube and probe showing region of investigation Product code & serial No. Probe Diameter 21.5mm Length 153mm Weight 0.13kg Connector type TNC Down-hole measurements at the Canning Archaelogical Site (USA) recording multiple paleosols (2Ab, 3Ab) and buried occupation layer (4Ab, 4Bw) Push tubes Construction Anodised aluminium alloy with BS015 `O` ring seal and stainless steel threaded couplings Lengths including union Upper - 101.5cm (extension) Lower - 91.5cm Weight 0.35kg each Connecting Cable Construction 10m length, 5mm diameter co-axial (may be extended to 100m max) Weight 0.4kg / 10m Carrying case Dimensions 1380 x 380 x 140mm Weight (full) 10kg 120cm 100cm 80cm 60cm 40cm 20cm 0cm 0.00E+000 4.00E+004 Soil profile from a nearby excavation Volume Susceptibility (SI) Specification - Equipment carrying case Weight 8-10kg including equipment Dimensions 550 x 480 x 280mm This handle is required for connection of the sensors type MS2D and MS2F to the MS2 meter. The handle is submersible to the depth of the electronics unit (0.6m). MS2 Equipment carrying case This is a tough lockable case with cut-outs to provide maximum protection for the equipment. MS2 Probe Handle Specification - MS2 Probe Handle Weight 0.6kg Dimensions - upper section 430mm length - lower section 360mm length Multisus Software AMSWIN-BAR Software This package is used with the MS2 meter and MS2B sensor to measure the anisotropy of magnetic susceptibility for magnetic fabric analysis. A sample adaptor, designed for 25mm diameter palaeomagnetic samples, is supplied with the software. The software operates under Windows® 2000/XP. A demonstration version can be downloaded from the Bartington web site. Multisus is used in conjunction with the MS2 meter and sensors type MS2B, MS2C, MS2E or MS2G. It can also be used with the down-hole probe type MS2H. It includes a facility for drift correction of measurements, performs corrections for the MS2C sensor core/coil diameter ratio, and for the MS2B sensor can convert readings to mass specific susceptibility and calculate the coefficient of frequency dependence of susceptibility. The software operates under Windows® 95/98/2000/NT/XP. It can be downloaded free of charge from the Bartington web site. Specification - MS2W Sensor Measurement sensitivity 1 x 10-5 SI (vol) (1 x 10-6 CGS) for 10ml sample, reduced by a factor of 4 for 2.5ml sample Calibration accuracy 1% (calibrated for 10ml sample) Measurement period - on x 1 range 2.4s SI (1.9s CGS) - on x 0.1 range 24s SI (19s CGS) Operating frequency 0.696kHz Drift during measurement <2 x 10-5 SI (vol) (<2 x 10-6 CGS)/30 minutes with 2l/minute water flow through sensor Weight 0.85kg Dimensions - probe internal ø 30mm - overall 255 x 100 x 65mm This system is used in the investigation of magnetic mineralogy and grain size and for the determination of Curie transition temperatures. It permits magnetic susceptibility measurements to be made on 15mm diameter (2.5ml) samples over the temperature range –200oC to +850oC. The system comprises the MS2 meter, MS2W sensor, MS2WF furnace, MS2WFP power supply unit and a selfcontained water coolant supply, fully interlocked to prevent MS2WF furnace operation without coolant flow. The Geolabsoft software package (running under Windows) collects data and displays the results during the measurement sequence.
MS2W Sensor This water-jacketed sensor has a 30mm diameter sample cavity. The temperature stability of the sensor is excellent and drift during the measurement sequence is exceptionally low as the water jacket thermally isolates the electronics from the sample cavity. The sensor can be used without the furnace or power supply, in conjunction with the MS2 meter and a non-magnetic type T thermocouple (Cu/Cu-Ni), for measurements on 10ml cylindrical samples over the temperature range -200oC to room temperature. The sample is cooled in liquid nitrogen and allowed to warm slowly to room temperature whilst measurements are taken. For high temperature measurements the MS2WF furnace and MS2WFP power supply unit are required.
MS2 Susceptibility/Temperature System Specification - MS2WF Furnance Weight 2kg Dimensions - Overall 350 x 235 x 135mm - Heating cavity 17mm ID 25mm usable height - Ceramic crucible cavity 13mm ID 20mm usable height MS2WF Furnace This furnace is installed inside the cavity of the water-jacketed sensor for heating samples from room temperature to +850OC. The non-inductively wound platinum heating element on a quartz cylinder ensures uniform heating of the sample whilst insulation reduces the maximum external temperature to around 100OC. The sample temperature is displayed on a digital panel meter to a resolution of 0.1OC when connected to a type S (Pt/Pt-Rh) or type T (Cu/Cu-Ni) thermocouple. The sample temperature is also available as an analog voltage. The sample diameter is restricted to 15mm maximum or circa 2.5ml volume. A ceramic crucible, specially designed to fit onto the thermocouple, is provided for granular or powder samples. Specification - MS2WFP Power Supply Unit Weight 7kg Dimensions 317 x 210 x 165 mm MS2WFP Power Supply Unit This unit supplies power to the MS2WF furnace to heat the sample. The sample temperature can be increased or decreased with a pre-selected linear rate or maintained at a pre-set level using manual controls. Geolabsoft software This software, for the Magnetic Susceptibility/Temperature System, runs under Windows 95/98/2000/NT/XP. Data is collected via a single RS232 serial interface and plotted in real time. Drift correction is applied at the end of the measurement sequence. Specifications of the products described in this brochure are subject to change without prior notice. Windows® is a registered trademark of Microsoft Corporation.
TURKEY DISTRUBUTORS: AND BİLİMSEL ANALİTİK TIBBİ CİHAZLAR LTD STİ HASDEMIR VILLAGES NUMBER 22 SUADIYE TURKEY: 00 90 262 352 24 25
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
30 kez incelendi.
|
|
|
|
|
|
 |
| |
| |
 |
Izmirtotem
|
| |
izmirde tabelacı,izmir tabela,izmirde totem,izmirde tot |
|
|
 |
Erol sevim
|
| |
HAYVAN BESİCİLERİNE SÜTÜ ARTIRAN BESİ HAYVANINA ET YAPT |
|
|
| |
 |
Konuk
|
| |
Müsyas otomatik musluk, fotoselli musluk, musluk aparat |
|
|
| |
| |
 |
Kastar emlak
|
| |
Kastar Emlaktan Ümraniye Çakmak,Çamlık Kiralık Daireler |
|
|
| |
| |
| |
|
|
 |
|
|
Sektorburada.com
|
| Bu grubu ziyaret et |
|
|
|